How to Design an Angled Attic Shower

Unusual angles and restricted access within an attic bath can make it tough to design a shower that fits to the space. With a few guidelines and building code requirements in mind, it’s likely to come up with a shower design that will nestle comfortably to a small loft toilet.

Minimum Size

The International Residential Code, the code on that most local building codes have been based, requires that the inside dimensions of a shower must be at least 30 by 30 inches and a 30-inch-diameter circle that specifies the minimum interior space must fit entirely within the shower. The National Kitchen and Bath Association, however, recommends a minimum inside space of at least 36 inches in diameter. A shower with an angled door, a design commonly used while the shower is located at a corner, needs to be wider than 30 inches to accommodate the minimum 30-inch circle; the IRC specifies a interior size of 32 by 32 inches in this situation.

Controls and Shower Head

The NKBA recommends that the shower controls be available from outside the shower spray region and located 38 to 48 inches from the Landscaping flowers Fresno. The shower head ought to be 63 to 81 inches over the Landscaping price Littleton and needs to be found within the IRC’s 30-inch circle. In an attic space with a low ceiling, a shower head height of 81 ins might be impossible. The NKBA suggests a shower head height of 75 inches is acceptable for consumers under 6 feet tall.

Ceiling Height

The IRC requires that Designer Bathroom Concepts Pittsburgh ceilings be at least 80 inches high. In the event of an attic with a sloped ceiling, the ceiling may drop as low as 60 inches in regions where it is not possible for everyone to walk. However, within the shower, the ceiling must be at least 80 inches high anywhere within the 30 by 30 inch minimum dimension around the shower head. The ceiling must also be at least 80 inches high above the crystal clear floor area in front of the shower door.

Surround Height

The IRC claims the walls of the shower must be covered with a watertight material to a height of at least 72 inches above the Landscaping cost Fresno. The NKBA agrees but advocates the waterproof material stretch at least 3 inches above the shower head. The NKBA also advocates the shower door and enclosure not stretch all the way to the ceiling so that steam is able to escape.

Clear Space and Doors